代写EEEE3086 H63EEJ Optical Networks代写留学生Matlab语言

H63EEJ Optical Networks

09 January 2022

Coursework:

“Design of the Local Optical Fibre Network”

25% course work 12.5 hours student time. Up to 3000 words CWK on passive Optical Network components.

Report Deadline: 4th May 2023

AIM

Your aim is to design local optical fibre network that consists of a minimum 3 passive and 1 active optical communication component. In your design, you will need to calculate losses in the optical network and describe your approach. You will also need to calculate mean down time of the design network by providing appropriate values for Failure Rate and Mean Time to Repair of each of the used components.

In your max 3000 words report you will need to:

1. Demonstrate a basic understanding of the principle of design of the local optical fibre networks.

2. Demonstrate a basic understanding of the principle of operations of the used in your design passive and active optical network components.

3. List main functionalities of the used in your design passive and active optical network components.

4. Sketch the designed network clearly labelling all components used.

5. Calculate losses in the optical network.

6. Describe and discuss your findings in terms of losses, risks and what can be done to minimise those losses and mitigate the risks.

7. Calculate the Mean Down Time of the design network.

Theory

Passive/access optical network: 

Access network connects the exchanges (that were interconnected by the metro network) to the ultimate user (home or business) by a variety of techniques.

When fibre is used the optical network units/terminations (ONUs/ONTs) may be connected point to point or in a tree/branch configuration (often called a ‘passive optical network’ (PON)) to the OLT in the nearest exchange. Access rings are also sometimes used.

Both access networks and metro/regional networks can improve their survivability (ability to function in the event of loss of node or link) by dual homing, which basically means two connections into thPhysically the PON connects an OLT (with one or more wavelengths) to optical network units (ONUs) which may be located in homes (fibre-to-the-home: FTTH), in buildings (fibre-to-the-building: FTTB or fibre-to-the-premises: FTTP), to the kerb (FTTK: fibre-to-the-kerb) etc. The network topology is usually tree/branch. In fact the name PON is typically synonymous with that topology.

Passive optical components:

Coupler/splitter

Isolator

Circulator

Filter/multiplexer

Array waveguide grating

Mach-Zehnder interferometer (MZI)

Variable optical attenuator

Active optical components:

Transmitters

Amplifiers

Receivers

Mean down time calculations:

1. In the following simple PON network calculate the mean down time (in min/year) experienced by ONUs.

Assume the following data:

The length of fibre between ONU and nearest splitter is 0.5 km, between the splitters is 1.5 km, and the feeder is 8 km long.

Failure rate (in FITs – failures in 109 hours): LT = 3000, Splitter = 250, NU = 800, fibre (per km) = 2500 (this is due to a cable cut rather than an actual failure of the fibre/cable material). [You will need to calculate the Mean Time Between Failures (MTBF) from these values]

Mean Time to Repair (MTTR): LT = 4 hours, Feeder fibre = 5 hours, Splitter = 10 hours, Distribution fibre = 10 hours, NU = 36 hours

Show diagrammatically, and with the appropriate calculation how we might (economically) improve the MDT to less than 53 min/year.

We are trying to find the mean down time (MDT) experienced by the users of the network. So we want the probability of unavailability.

For the OLT have pdOLT=MTTROLT/(MTTROLT+MTBFOLT)

But MTBFOLT (in hours)=1/failure rate per hour = 109/FITrate  =109/3000

(FITrate is failures per 109 hours)

So pdOLT=MTTROLT/(MTTROLT+MTBFOLT)=4/(4+109/3000)=1.20x10-5

MDTOLT=pdOLTx365x24x60=6.31 min/year

For the ONU:

pdONU=MTTRONU/(MTTRONU+MTBFONU)=36/(36+109/800)=2.88x10-5

MDTONU=pdONUx365x24x60=15.14 min/year

For the feeder:

pdfeeder=MTTRfeeder/(MTTRfeeder+MTBFfeeder)=5/(5+109/(2500x8))=1.00x10-4

MDTfeeder=pdfeederx365x24x60=52.55 min/year

For the distribution fibre:

pddistrib=MTTRdistrib/(MTTRdistrib+MTBFdistrib)=10/(10+109/(2500x(1.5+0.5)))=5.00x10-5

MDTdistrib=pddistribx365x24x60=26.28 min/year

For the splitters (both the same):

pdsplitter=MTTRsplitter/(MTTRsplitter+MTBFsplitter)=10/(10+109/250)=2.49x10-6

MDTsplitter=pdsplitterx365x24x60=1.31 min/year

As all the downtime probabilities are small we can neglect the probability of multiple failures occurring at the same time and write that:

MDTsystem= MDTOLT+ MDTfeeder+ MDTsplitterx2+ MDTdistrib+ MDTONU

    =6.31+52.55+2.62+26.28+15.14

    =102.9 min/year

This is, to a good approximation, what we might expect an ONU/user to experience on average.

We can (without too much extra expense) improve the MDT to less than 53 min/year by having a redundant diversely routed protection feeder.

This protection approximately reduces the system MDT to 102.9-52.55=50.35 min/yr

More accurately use pdfeedercombination=(pdfeeder)2  =10-8

Which we see is negligible! (even compared to splitter!)

 


热门主题

课程名

mktg2509 csci 2600 38170 lng302 csse3010 phas3226 77938 arch1162 engn4536/engn6536 acx5903 comp151101 phl245 cse12 comp9312 stat3016/6016 phas0038 comp2140 6qqmb312 xjco3011 rest0005 ematm0051 5qqmn219 lubs5062m eee8155 cege0100 eap033 artd1109 mat246 etc3430 ecmm462 mis102 inft6800 ddes9903 comp6521 comp9517 comp3331/9331 comp4337 comp6008 comp9414 bu.231.790.81 man00150m csb352h math1041 eengm4100 isys1002 08 6057cem mktg3504 mthm036 mtrx1701 mth3241 eeee3086 cmp-7038b cmp-7000a ints4010 econ2151 infs5710 fins5516 fin3309 fins5510 gsoe9340 math2007 math2036 soee5010 mark3088 infs3605 elec9714 comp2271 ma214 comp2211 infs3604 600426 sit254 acct3091 bbt405 msin0116 com107/com113 mark5826 sit120 comp9021 eco2101 eeen40700 cs253 ece3114 ecmm447 chns3000 math377 itd102 comp9444 comp(2041|9044) econ0060 econ7230 mgt001371 ecs-323 cs6250 mgdi60012 mdia2012 comm221001 comm5000 ma1008 engl642 econ241 com333 math367 mis201 nbs-7041x meek16104 econ2003 comm1190 mbas902 comp-1027 dpst1091 comp7315 eppd1033 m06 ee3025 msci231 bb113/bbs1063 fc709 comp3425 comp9417 econ42915 cb9101 math1102e chme0017 fc307 mkt60104 5522usst litr1-uc6201.200 ee1102 cosc2803 math39512 omp9727 int2067/int5051 bsb151 mgt253 fc021 babs2202 mis2002s phya21 18-213 cege0012 mdia1002 math38032 mech5125 07 cisc102 mgx3110 cs240 11175 fin3020s eco3420 ictten622 comp9727 cpt111 de114102d mgm320h5s bafi1019 math21112 efim20036 mn-3503 fins5568 110.807 bcpm000028 info6030 bma0092 bcpm0054 math20212 ce335 cs365 cenv6141 ftec5580 math2010 ec3450 comm1170 ecmt1010 csci-ua.0480-003 econ12-200 ib3960 ectb60h3f cs247—assignment tk3163 ics3u ib3j80 comp20008 comp9334 eppd1063 acct2343 cct109 isys1055/3412 math350-real math2014 eec180 stat141b econ2101 msinm014/msing014/msing014b fit2004 comp643 bu1002 cm2030